Back to allproducts.com Back to allproducts.com
Searching products in allproducts.com:
Free to Submit Your Products | Trade Leads | Sourcing Requirement | Help
 
Home > Products > Electrical and Electronics > Test & Measuring Instruments > Measuring & Analysis Instrument > Logic Analyzers
Navigation
Company
Showroom
Inquiry

LINEEYE Co., Ltd.

Print this page Send an inquiry
Product  

Product ID: LE-2100

Multi Protocol Analyzer

Supports Max. 115.2Kbps, Communications analyzer comes standard with simulation.
Synchronous and Asynchronous are possible to be monitored up to 115.2kbps. LE-2100 is those kind of high-performance analyzer which is capable of monitoring, simulation and BERT.
Supports PPP (point - to - point protocol), translation of HDLC and X.25.
Not only RS-232C of a standard inerface but also expandability supports RS-422/485, X.21, V.35, current loop, TTL and IrDA with option adapter.



Multi Protocol Analyzer(LE-2100)

Click here for details.


Interface Standard RS-232C / V.24
Interface Option Current loop, RS-422, RS-485, X. 20 / 21. V.35, TTL, IrDA
Protocol Asynchronous ASYNC Character synchronous: SYNC, BSC, Bit-oriented synchronous: HDLC, SDLC, X.25 (NRZ / NRZI)
Data Transmission Speed Max. 115.2 Kbps in all protocols / modes
Internal Clock (bps) [Can be set for transmission and reception independently] 50, 75, 100, 110, 134.5, 150, 200, 300, 600, 1200, 1800, 2000, 2400, 3200, 3600, 4800, 7200,8000, 9600, 12000, 12800, 14400, 16000*, 168000*, 19200, 28800, 32000*, 38400, 46000, 48000*, 50000*, 56000*, 57600, 64000*, 72000*, 76800, 115200 (*Measurements extracting synchronous clock from the received data are impossible at these speeds.)
Data Code ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX
Character Framing Asynchronous: Data bit (5 / 6 / 7 / 8) + parity bit (0 / 1) + stop bit (1 / 1.5 / 2) Character synchronous: Data bit + parity bit (total 6, 8 bits) Bit-oriented synchronous: Data bit + Parity bit (total 8 bits).
Parity Bit None, odd, even, mark, space
Bit Transmission Order LSB first or MSB first, selectable
Polarity Inversion Normal or inverted, selectable
Error Check Function Parity (none, odd, even, mark, space), framing, abort, short, frame, BCC (none, LRC, CRC-6, CRC-12, CRC- 16, CRC-ITU-T)
Memory capacity [Data retainable] Capture memory for monitor: 192K bytes (96K characters) Expandable up to 1.216M bytes with memory card. One area or two divided areas, selectable Simulation transmission data memory: 8192 characters Divisible into a maximum of 16 types data string.
On-line Monitor Function Handles half-duplex and full-duplex communications. Idle time display (max. 999.9s; resolution: 10ms, 100ms), Time stamp (Records and displays time in day / hour / minute or hour / minute / second basis.), Capture display pause, bit shift display in SYNC and jump to the specified screen enabled.
Protocol Translation Display Function SDLC translation, ITU-TX.25 frame / packet translation, BSC translation
Interface Signal Status Display Function 3-value indication (ON / OFF/ NC) with 2-color LED: SD, RD, RS, CS, ER, DR, CD, SQD, CI, ST1, ST2 and RT Timing waveform and transmitted / received data displayed on LCD: Four signals selectable from RS, CS, ER, DR, CD, SQD, CI and external input
Data Retrieval Function Retrieves data conforming to the condition from memory and displays / counts them.
Monitor Condition Automatic Setting Function Measurement conditions such as protocol, transmission speed (50-115.2Kbps), data code, synchronous character and BCC check can be set.
Auto Run / Stop Function Start and stop time of various measurement tests can be specified.
Delay Time Measurement Measures and displays the time between interface signal line changes(0.1 ms resolution).
Timer / Counter Interval timer: (2 kinds) Max. 655.35s or 6553.5s selectable; Universal counter: (2 kinds) Max. 65535 Counter for SD / RD characters: Max. 4294967295
Trigger Function Four pairs of "condition" and "action" to be taken when the condition is satisfied can be set. Trigger condition: Preset character ("don't care" and bit masking assignable; up to 8 characters ). idle time not less than preset value, preset time stamp ("don't care" assignable), error ( error type individually assignable), timer/counter value matching, logical status of interface signal line, external trigger input, and capture memory full Trigger action: Stop measurement test (offset assignable), timer control ( start / stop / restart), counter control (count / clear), buzzer, external signal output, save monitor data onto memory card, send preset characters (for simulation)
Bit Error Rate Test (BERT) Function Error rate measurement test in accordance with ITU-T recommendation G.82 is possible. Pattern : 2&sup6;-1.2&sup9;-1.2¹1;-1,mark, space Measurement range: Bit error counting, block error counting (0-9999999-9.99E9), bit error rate, block error rate, SYNC loss frequency, Savail (operating time), %EFS (normal operation rate); ASYNC or SYNC mode selectable, error bit insertion enabled with key operation
Simulation Functions Enables communications procedures to be checked using the desired simulation data in test mode according to the phase of equipment development.
Manual Test Sets of data are assigned to operation keys; data are sent by pressing the key while checking the received data on LCD.
Match Test Sends specified data when the trigger condition is satisfied. (Used together with trigger function.)
Flow Control Test Flow control simulation by X-on/off or RTS/CTS (sender / receiver selectable).
Echo Test Loop back transmission of received data (by bit, data or frame).
Multi-polling test Simulates multi-polling communications procedure.
Display Monochrome LCD without back-light (Max. 30 characters, 8 lines).
Memory Card Interface 256KB - 1MB SRAM card
Memory Card Interface File mode: Capable of saving/loading setup information, data for simulation and monitor data (up to 100 files) Buffer mode: Can be used as expanded buffer memory for capture.
External Serial Interface RS-232C (mini DIN 8-pin); setting conditions, simulation data and monitor data can be input from or output to external devices.
Printer Interface Centronics standard (14-pin anphenol type) or RS-232C (mini DIN 8-pin), selectable; Hard copy of LCD screen and printing monitor data on continuous format.
Power Supply Self-contained Ni-Cd cell or AC adapter (AC 100-240 V, 50/60Hz)
Battery 6 hours
Dimensions / Weight 39(H), 240(W), 170(D)mm, Approx. 950g
Environmental Requirement Working temperature range: 0 to 40celsius; Storage temperature range: -10 to 50celsius; Humidity: 90% RH or below (no condensation)
Accessories RS-232C/V.24 monitor cable : 1; AC adapter : 1; Carrying bag : 1; Instruction manual : 1