No longer sell Multi Protocol Analyzer
Supports Max. 115.2Kbps, Program simulation as a standard feature.
LE-3100 can monitor synchronous and asynchronous up to 115.2 Kbps in real time.
High-performance communications analyzer capable of monitoring, simulation and BERT.
Supports RS-232C as a standard feature and RS-422 / 485, X.21, V.35, current loop, TTL, IrDA with an optional adapter.
LE-3100 was added features of statistical analysis capabilities, buffer simulation and program simulation to feature of LE-2100, and got legible LCD with back-light.
Not only using in the field but Le-3100 also using it for testing of full-scale communication systems in research and development post.
| Interface Standard | RS-232C / V.24 | |
|---|---|---|
| Interface Option | Current loop, RS-422, RS-485, X. 20 / 21. V.35 TTL, IrDA. | |
| Protocol | Asynchronous ASYNC Character synchronous: SYNC, BSC, Bit-oriented synchronous HDLC, SDLC X.25 (NRZ / NRZI). | |
| Data Transmission Speed | Max. 115.2 Kbps in all protocols / modes. | |
| Internal Clock (bps) [Can be set for transmission and reception independently] | 50, 75, 100, 110, 134.5, 150, 200, 300, 600, 1200, 1800, 2000, 2400, 3200, 3600, 4800, 7200, 8000, 9600, 12000, 12800, 14400, 16000*, 16800*, 19200, 28800, 32000*, 38400, 46000, 48000*, 50000*, 56000*, 57600, 64000*, 72000*, 76800, 115200 (*Measurements extracting synchronous clock from the received data are impossible at these speeds.) | |
| Data Code | ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX. | |
| Character Framing | Asynchronous: Data bit (5 / 6 / 7 / 8) + parity bit (0 / 1) + stop bit (total 1 / 1.5 / 2) Character synchronous: Data bit + parity bit (total 6, 8 bits) Bit-oriented synchronous: Data bit + Parity bit (total 8 bits). | |
| Parity Bit | None, odd, even, mark, space | |
| Bit Transmission Order | LSB first or MSB first, selectable. | |
| Polarity Inversion | Normal or inverted, selectable. | |
| Error Check Function | Parity (none, odd, even, mark, space), framing, abort, short, frame, BCC (none, LRC, CRC-6, CRC-12, CRC- 16, CRC-ITU-T). | |
| Memory capacity [Data retainable] | Capture memory for monitor : 192K bytes (96K characters) Expandable up to 1.216M bytes with memory card. One area or two divided areas, selectable Simulation transmission data memory: 8192 characters Divisible into a maximum of 16 types data string. | |
| On-line Monitor Function | Handles half-duplex and full-duplex communications. Idle time display (max. 999.9s; resolution: 10ms, 100ms), Time stamp (Records and displays time in day / hour / minute or hour / minute / second basis.),Capture display pause, bit shift display in SYNC and jump to the specified screen enabled. | |
| Protocol Translation Display Function | SDLC translation, ITU-TX.25 frame / packet translation , BSC translation. | |
| Interface Signal Status Display Function | 3-value indication (ON / OFF/ NC) with 2-color LED: SD, RD, RS, CS, ER, DR, CD, SQD, CI, ST1, ST2 and RT Timing waveform and transmitted / received data displayed on LCD: Four signals selectable from RS, CS, ER, DR, CD, SQD, CI and external input. | |
| Data Retrieval Function | Retrieves data conforming to the condition from memory and displays / counts them. | trieval condition: Preset characters (*quot;don't care" and bit masking assignable; up to 8 characters), idle time not less than preset value, time stamp data ("don't care" and bit masking assignable) error (parity, framing, BCC, break / abort, short frame individually assignable) and trigger point. |
| Monitor Condition Automatic Setting Function | Measurement conditions such as protocol, transmission speed (50-115.2Kbps), data code, synchronous character and BCC check can be set. | |
| Auto Run / Stop Function | Start and stop time of various measurement tests can be specified. | |
| Delay Time Measurement | Measures and displays the time between interface signal line changes(0.1 ms resolution). | |
| Timer / Counter | Interval timer: (2 kinds) Max. 655.35s or 6553.5s selectable; Universal counter: (2 kinds) Max. 65535 Counter for SD / RD characters: Max. 4294967295. | |
| Statistical analysis function | No. of exchanged characters, no. of frames, no. of satisfied trigger conditions are displayed in graphs. | |
| Trigger Function | Four pairs of "condition" and "action" to be taken when the condition is satisfied can be set. Trigger condition: Preset character ("don't care" and bit masking assignable; up to 8 characters ). idle time not less than preset value, preset time stamp ("don't care" assignable), error ( error type individually assignable), timer/counter value matching, logical status of interface signal line, external trigger input, and capture memory full Trigger action: Stop measurement test (offset assignable), timer control ( start / stop / restart), counter control (count / clear), buzzer, external signal output, save monitor data onto memory card, send preset characters (for simulation). | |
| Bit Error Rate Test (BERT) Function | Error rate measurement test in accordance with ITU-T recommendation G.82 is possible. Pattern : 2&sup6;-1.2&sup9;-1.2¹1;-1,mark, space Measurement range: Bit error counting, block error counting (0-9999999-9.99E9), bit error rate, block error rate, SYNC loss frequency, Savail (operating time), %EFS (normal operation rate); ASYNC or SYNC mode selectable, error bit insertion enabled with key operation. | |
| Simulation Functions | Enables communications procedures to be checked using the desired simulation data in test mode according to the phase of equipment development. | |
| Manual Test | Sets of data are assigned to operation keys; data are sent by pressing the key while checking the received data on LCD. | |
| Match Test | Sends specified data when the trigger condition is satisfied. (Used together with trigger function.) | |
| Flow Control Test | Flow control simulation by X-on/off or RTS/CTS (sender / receiver selectable). | |
| Echo Test | Loop-back transmission of received data (by bit, data or frame). | |
| Multi-polling test | Simulates multi-polling communications procedure. | |
| Buffer transmission test | Sends SD and RD of capture data. | |
| Program simulation | No. of program commands : 32; No. of program steps : 512; Transmitted message : Max. 8192 characters; Interface signal : Programmed control possible | |
| Display | Monochrome LCD with back-light (Max. 30 characters, 8 lines). | |
| Memory Card Interface | 256KB- 1MB SRAM card. | |
| Memory Card Interface | File mode: Capable of saving/loading setup information, data for simulation and monitor data ( up to 100 files) Buffer mode : Can be used as expanded buffer memory for capture. | |
| External Serial Interface | RS-232C (mini DIN 8-pin); setting conditions, simulation data and monitor data can be input from or output to external devices. | |
| Printer Interface | Centronics standard (14-pin anphenol type) or RS-232C (mini DIN 8-pin), selectable; Hard copy of LCD screen and printing monitor data on continuous format. | |
| Power Supply | Self-contained Ni-Cd cell or AC adapter (AC 100-240V, 50/60Hz). | |
| Battery | 6 hours (with back-light off). | |
| Dimensions / Weight | 39(H), 240(W), 170(D)mm, approx. 980g. | |
| Environmental Requirement | Working temperature range : 0 to 40celsius; Storage temperature range : -10 to 50celsius; Humidity : 90% RH or below (no condensation). | |
| Accessories | RS-232C/V.24 monitor cable : 1; AC adapter : 1; Carrying bag : 1; Instruction manual : 1 |
Main Products: