Supports Max. 115.2Kbps, Program simulation as a standard feature.
LE-3100 can monitor synchronous and asynchronous up to 115.2 Kbps in real time.
High-performance communications analyzer capable of monitoring, simulation and BERT.
Supports RS-232C as a standard feature and RS-422 / 485, X.21, V.35, current loop, TTL, IrDA with an optional adapter.
LE-3100 was added features of statistical analysis capabilities, buffer simulation and program simulation to feature of LE-2100, and got legible LCD with back-light.
Not only using in the field but Le-3100 also using it for testing of full-scale communication systems in research and development post.


Interface Standard RS-232C / V.24
Interface Option Current loop, RS-422, RS-485, X. 20 / 21. V.35 TTL, IrDA.
Protocol Asynchronous ASYNC Character synchronous: SYNC, BSC, Bit-oriented synchronous HDLC, SDLC X.25 (NRZ / NRZI).
Data Transmission Speed Max. 115.2 Kbps in all protocols / modes.
Internal Clock (bps) [Can be set for transmission and reception independently] 50, 75, 100, 110, 134.5, 150, 200, 300, 600, 1200, 1800, 2000, 2400, 3200, 3600, 4800, 7200, 8000, 9600, 12000, 12800, 14400, 16000*, 16800*, 19200, 28800, 32000*, 38400, 46000, 48000*, 50000*, 56000*, 57600, 64000*, 72000*, 76800, 115200 (*Measurements extracting synchronous clock from the received data are impossible at these speeds.)
Data Code ASCII, EBCDIC, JIS7, JIS8, Baudot, Transcode, IPARS, EBCD, EBCDIK, HEX.
Character Framing Asynchronous: Data bit (5 / 6 / 7 / 8) + parity bit (0 / 1) + stop bit (total 1 / 1.5 / 2) Character synchronous: Data bit + parity bit (total 6, 8 bits) Bit-oriented synchronous: Data bit + Parity bit (total 8 bits).
Parity Bit None, odd, even, mark, space
Bit Transmission Order LSB first or MSB first, selectable.
Polarity Inversion Normal or inverted, selectable.
Error Check Function Parity (none, odd, even, mark, space), framing, abort, short, frame, BCC (none, LRC, CRC-6, CRC-12, CRC- 16, CRC-ITU-T).
Memory capacity [Data retainable] Capture memory for monitor : 192K bytes (96K characters) Expandable up to 1.216M bytes with memory card. One area or two divided areas, selectable Simulation transmission data memory: 8192 characters Divisible into a maximum of 16 types data string.
On-line Monitor Function Handles half-duplex and full-duplex communications. Idle time display (max. 999.9s; resolution: 10ms, 100ms), Time stamp (Records and displays time in day / hour / minute or hour / minute / second basis.),Capture display pause, bit shift display in SYNC and jump to the specified screen enabled.
Protocol Translation Display Function SDLC translation, ITU-TX.25 frame / packet translation , BSC translation.
Interface Signal Status Display Function 3-value indication (ON / OFF/ NC) with 2-color LED: SD, RD, RS, CS, ER, DR, CD, SQD, CI, ST1, ST2 and RT Timing waveform and transmitted / received data displayed on LCD: Four signals selectable from RS, CS, ER, DR, CD, SQD, CI and external input.
Data Retrieval Function Retrieves data conforming to the condition from memory and displays / counts them. trieval condition: Preset characters (*quot;don't care" and bit masking assignable; up to 8 characters), idle time not less than preset value, time stamp data ("don't care" and bit masking assignable) error (parity, framing, BCC, break / abort, short frame individually assignable) and trigger point.
Monitor Condition Automatic Setting Function Measurement conditions such as protocol, transmission speed (50-115.2Kbps), data code, synchronous character and BCC check can be set.
Auto Run / Stop Function Start and stop time of various measurement tests can be specified.
Delay Time Measurement Measures and displays the time between interface signal line changes(0.1 ms resolution).
Timer / Counter Interval timer: (2 kinds) Max. 655.35s or 6553.5s selectable; Universal counter: (2 kinds) Max. 65535 Counter for SD / RD characters: Max. 4294967295.
Statistical analysis function No. of exchanged characters, no. of frames, no. of satisfied trigger conditions are displayed in graphs.
Trigger Function Four pairs of "condition" and "action" to be taken when the condition is satisfied can be set. Trigger condition: Preset character ("don't care" and bit masking assignable; up to 8 characters ). idle time not less than preset value, preset time stamp ("don't care" assignable), error ( error type individually assignable), timer/counter value matching, logical status of interface signal line, external trigger input, and capture memory full Trigger action: Stop measurement test (offset assignable), timer control ( start / stop / restart), counter control (count / clear), buzzer, external signal output, save monitor data onto memory card, send preset characters (for simulation).
Bit Error Rate Test (BERT) Function Error rate measurement test in accordance with ITU-T recommendation G.82 is possible. Pattern : 2&sup6;-1.2&sup9;-1.2¹1;-1,mark, space Measurement range: Bit error counting, block error counting (0-9999999-9.99E9), bit error rate, block error rate, SYNC loss frequency, Savail (operating time), %EFS (normal operation rate); ASYNC or SYNC mode selectable, error bit insertion enabled with key operation.
Simulation Functions Enables communications procedures to be checked using the desired simulation data in test mode according to the phase of equipment development.
Manual Test Sets of data are assigned to operation keys; data are sent by pressing the key while checking the received data on LCD.
Match Test Sends specified data when the trigger condition is satisfied. (Used together with trigger function.)
Flow Control Test Flow control simulation by X-on/off or RTS/CTS (sender / receiver selectable).
Echo Test Loop-back transmission of received data (by bit, data or frame).
Multi-polling test Simulates multi-polling communications procedure.
Buffer transmission test Sends SD and RD of capture data.
Program simulation No. of program commands : 32; No. of program steps : 512; Transmitted message : Max. 8192 characters; Interface signal : Programmed control possible
Display Monochrome LCD with back-light (Max. 30 characters, 8 lines).
Memory Card Interface 256KB- 1MB SRAM card.
Memory Card Interface File mode: Capable of saving/loading setup information, data for simulation and monitor data ( up to 100 files) Buffer mode : Can be used as expanded buffer memory for capture.
External Serial Interface RS-232C (mini DIN 8-pin); setting conditions, simulation data and monitor data can be input from or output to external devices.
Printer Interface Centronics standard (14-pin anphenol type) or RS-232C (mini DIN 8-pin), selectable; Hard copy of LCD screen and printing monitor data on continuous format.
Power Supply Self-contained Ni-Cd cell or AC adapter (AC 100-240V, 50/60Hz).
Battery 6 hours (with back-light off).
Dimensions / Weight 39(H), 240(W), 170(D)mm, approx. 980g.
Environmental Requirement Working temperature range : 0 to 40celsius; Storage temperature range : -10 to 50celsius; Humidity : 90% RH or below (no condensation).
Accessories RS-232C/V.24 monitor cable : 1; AC adapter : 1; Carrying bag : 1; Instruction manual : 1