Minsun Technology Co., Ltd.

Send an inquiry
Kilowatt Hour Meter

Product ID: MSDP-700

Kilowatt Hour Meter

Kilowatt Hour Meter (MSDP-700)

MSDP-700 kilowatt-hour meter shows the reading of power consuming directly in LED display (The unit is KW or MW), It no need to multiply with PT/CT ratio, data the clear and legible.
There is MSDP700-30A model besides, needn't CT can suitable for the occasion under 30 amperes.

Features:
  • 6-figure number large-scale LED shows, clear, legible.
  • Can be set up PT, CT ratio by the panel directly, it is all suitable that various kinds of electric panel.
  • Can set up the-figure number of the decimal point.
  • Set up and protect carefully, can prevent non-relevant personl from revising or setting up.
  • Export kilowatt-hour Pulse, can connect the central monitoring system directly.
  • Suitable for the high, low-voltage equipment of factory, and the market, suite, etc.
  • Size: High 144 x wide 144 x deep 105 mm (MSDP-700-30A/M wires length about 10 centimeters).
  • Panel cut out: 138 x 138 mm.

Item MSDP-700 MSDP-700M MSDP-700-30A MSDP-700-30AM
Input voltage 0-510V
(single-phase or three phases)
0-510V
(single-phase or three phases)
0-510V
(single-phase or three phases)
0-510V
(single-phase or three phases)
Input current 0-5A
(single-phase or three phases)
0-5A
(single-phase or three phases)
0-30AA
(single-phase or three phases)
0-30AA
(single-phase or three phases)
Accuracy ± 1% F.S. ± 1% F.S. ± 1% F.S. ± 1% F.S.
Pulse exporting NPN contact
(whether Pulse rate can changed by set up)
NPN contact
(whether Pulse rate can changed by set up)
NPN contact
(whether Pulse rate can changed by set up)
NPN contact
(whether Pulse rate can changed by set up)
Communication function - RS-485/MODBUS - RS-485/MODBUS
Protected mode By short terminal at the equipment back,
make the panel set up
and protected losing efficiency
By short terminal at the equipment back,
make the panel set up
and protected losing efficiency
By short terminal at the equipment back,
make the panel set up
and protected losing efficiency
By short terminal at the equipment back,
make the panel set up
and protected losing efficiency
Memory that lose electrical power The inside data can be kept
for more than two months
while losing electrical power
The inside data can be kept
for more than two months
while losing electrical power
The inside data can be kept
for more than two months
while losing electrical power
The inside data can be kept
for more than two months
while losing electrical power
The panel showing 6 persons of large-scale digital display 6 persons of large-scale digital display 6 persons of large-scale digital display 6 persons of large-scale digital display
Working power 110V,220V,380V, 440V±15%
Frequency 45-65HZ;
Power consumption 10VA (max.)
110V,220V,380V, 440V±15%
Frequency 45-65HZ;
Power consumption 10VA (max.)
220V, 380V±15%; Frequency 45-65HZ;
Power consumption 10VA (max.)
220V, 380V±15%; Frequency 45-65HZ;
Power consumption 10VA (max.)

Main Products:
Electric Meter, Plating Equipment, Galvanizing Equipment, Electric Demand Control, Electric Power Meter, Multi-Function Power meter, Kilowatt Hour Meter, Power Factor Regulator, Multi-functional Electric Converter, Four Section Demand Controller, Distributed / High Performance Demand Control System,

Send an inquiry

Contact Details

Minimum Order:Negotiable
Address:No.15, Lane 210, Jeanshin St. Shulin City Taipei Hsien, Taiwan
Tel:886-2-2689-4051~2
Fax:886-2-2688-0109