AC/DC Power Supply 1U Redundant (New)
Product ID: PRTxxx1U-Sx/PRTxxx1U-Hx

1U Redundant (New Version Cold Swap), (New Version 1U+1), (New Version 1U+2).
This is new 1U Redundant power supply of PRT which presented in July 2006, and the series has promoted essential in 2008 by PRT.
Its wattage is from 325 ~ 750W.
- Input Voletge: 90Vac to 264Vac, with active power factor, PF=90% min.
- Input Frequency: 47 ~ 63Hz
- Input Leakage Current:
- Input leakage current from line to frame ground will be less than 3.5mA rms. foreach power module.
- Condition: 264Vac/60Hz
- Overshoot: Any output overshoots at TURN-ON shall not exceed 10% (+5V / +12V output) and 10% (-12V/ output) of nominal voltage value.
- Efficiency: 65% min. at full load test.
- Hold-Up Time: Unit shall continue to supply regulated DC outputs and power good signal for at least 16 Milliseconds at 115/230Vac full load after a loss of AC input voltage which shall be represented by a short circuit at the AC input.
- Over Power Protection
- CONDITION: Nominal input
- LIMITS: When output power is over to 120% ~ 150%
- Over Voltage Protection
- +5VDC
- CONDITION: All operating
- LIMITS: +5.7V ~ 6.7Vdc
- +3.3VDC
- CONDITION: All operating
- LIMITS: +3.7V ~ 4.7Vdc
- +12VDC
- CONDITION: All operating
- LIMITS: +Max. 13.0V ~ 15.0Vdc
- Short Circuit Protection:
- Short circuit placed on +3.3V / +5V / +12V / -12V output shall cause no damage to this unit.
- The power supply shall be shut down.
- AUTO-RECOVERED: 5VSB
- Environmental: Temperature
- Operating: 50 to 122°F (10 to 40°C). De-rate Linearly to 50% at 70°C
- Non-Operating: -4.0 to 140°F (-20 to 60°C)
- Environmental: Relative Humidity
- Operating: 20 to 90 % non-condensing at 104&ded;F (40°C)
- Non-Operating: 10 to 90 % non-condensing at 104°F (40°C)
- RFI/EMI Standards:
- FCC part 15, Subpart B, Class B computing device
- CISPR22 (EN55022) Class B.
- VCCI Class 2.
- Safety Standard:
- UL 60950-1
- C-UL
- UV Certification to IEC950 1 edition, and EN60950
- CE Certificate & Test Report
- Harmonic Requirement: IEC10000-3-2 & IEC10000-3-3 Class "D"
- Warranty: Two (2) years manufacture's warranty.
- UL
- TUV
- CB
- CE
| Model Number | Dimension (L x W x H) | Output Wattage | Option+5v | +3.3V | +12V | -12V | +5VSB | +5V, +3.3V Output |
|---|---|---|---|---|---|---|---|---|
| PRT3251U-S5 | 253 x 81 x 40 | 325W | 26A | 18A | 20A | 0.5A | 0A - 2A | 26A |
| PRT3251U-S2 | 253 x 81 x 40 | 325W | 26A | - | 20A | - | - | - |
| PRT3501U-S5 | 253 x 81 x 40 | 350W | 32A | 20A | 23A | 0.5A | 0A - 2A | 33A |
| PRT3751U-S5 | 253 x 81 x 40 | 375W | 32A | 20A | 26A | 0.5A | 0A - 2A | 33A |
| PRT4001U-S5 | 253 x 81 x 40 | 400W | 32A | 20A | 26A | 0.5A | 0A-2A | 33A |
| PRT4001U-S2 | 253 x 81 x 40 | 400W | 32A | - | 26A | - | - | - |
| PRT3251U-H5 | 288 x 162 x 42.5 | 325W | 26A | 18A | 20A | 0.5A | 0A-2A | 26A |
| PRT3251U-H2 | 288 x 162 x 42.5 | 325W | 26A | - | 20A | - | - | - |
| PRT3501U-H5 | 288 x 162 x 42.5 | 350W | 32A | 20A | 23A | 0.5A | 0A-2A | 33A |
| PRT4001U-H5 | 288 x 162 x 42.5 | 400W | 32A | 20A | 26A | 0.5A | 0A-2A | 33A |
| PRT4001U-H2 | 288 x 162 x 42.5 | 400W | 32A | - | 26A | - | - | - |
| PRT6001U-H5 | 288 x 270 x 42.5 | 600W | 50A | 36A | 40A | 0.5A | 0A-2A | 65A |
| PRT6001U-H2 | 288 x 270 x 42.5 | 600W | 50A | - | 40A | - | - | - |
| PRT6501U-H5 | 288 x 270 x 42.5 | 650W | 50A | 38A | 46A | 0.5A | 0A-2A | 65A |
| PRT7001U-H5 | 288 x 270 x 42.5 | 700W | 50A | 40A | 52A | 0.5A | 0A-2A | 65A |
| PRT7501U-H2 | 288 x 270 x 42.5 | 750W | 60A | - | 52A | - | - | - |
| PRT7501U-H5 | 288 x 270 x 42.5 | 750W | 50A | 40A | 52A | 0.5A | 0A-2A | 65A |
Main Products:
Redundant Power Supply, Open Frame Power Supply, ATX Power Supply, AC/DC Power Supply, 1U Power Supply
Related Products
Contact Details
CEO: Mr. Jason Pan
Minimum Order:Negotiable
Address:No. 693, Jhongjheng Rd., Shulin City Taipei County, 238 Taiwan
Tel:886-2-26882181
Fax:886-2-26882189
E-mail:
service@prt.com.tw