Power Research Technology Co., Ltd.

Send an inquiry
AC/DC Power Supply 1U Redundant (New)

Product ID: PRTxxx1U-Sx/PRTxxx1U-Hx

AC/DC Power Supply 1U Redundant (New)

1U Redundant 1+1

product pic

1U Cold Swap

1U Redundant (New Version Cold Swap), (New Version 1U+1), (New Version 1U+2).


This is new 1U Redundant power supply of PRT which presented in July 2006, and the series has promoted essential in 2008 by PRT.
Its wattage is from 325 ~ 750W.

Specifications:
  • Input Voletge: 90Vac to 264Vac, with active power factor, PF=90% min.
  • Input Frequency: 47 ~ 63Hz
  • Input Leakage Current:
    • Input leakage current from line to frame ground will be less than 3.5mA rms. foreach power module.
    • Condition: 264Vac/60Hz
  • Overshoot: Any output overshoots at TURN-ON shall not exceed 10% (+5V / +12V output) and 10% (-12V/ output) of nominal voltage value.
  • Efficiency: 65% min. at full load test.
  • Hold-Up Time: Unit shall continue to supply regulated DC outputs and power good signal for at least 16 Milliseconds at 115/230Vac full load after a loss of AC input voltage which shall be represented by a short circuit at the AC input.
  • Over Power Protection
    • CONDITION: Nominal input
    • LIMITS: When output power is over to 120% ~ 150%
  • Over Voltage Protection
    • +5VDC
      • CONDITION: All operating
      • LIMITS: +5.7V ~ 6.7Vdc
    • +3.3VDC
      • CONDITION: All operating
      • LIMITS: +3.7V ~ 4.7Vdc
    • +12VDC
      • CONDITION: All operating
      • LIMITS: +Max. 13.0V ~ 15.0Vdc
    • Short Circuit Protection:
      • Short circuit placed on +3.3V / +5V / +12V / -12V output shall cause no damage to this unit.
      • The power supply shall be shut down.
      • AUTO-RECOVERED: 5VSB
    • Environmental: Temperature
      • Operating: 50 to 122°F (10 to 40°C). De-rate Linearly to 50% at 70°C
      • Non-Operating: -4.0 to 140°F (-20 to 60°C)
    • Environmental: Relative Humidity
      • Operating: 20 to 90 % non-condensing at 104&ded;F (40°C)
      • Non-Operating: 10 to 90 % non-condensing at 104°F (40°C)
    • RFI/EMI Standards:
      • FCC part 15, Subpart B, Class B computing device
      • CISPR22 (EN55022) Class B.
      • VCCI Class 2.
    • Safety Standard:
      • UL 60950-1
      • C-UL
      • UV Certification to IEC950 1 edition, and EN60950
      • CE Certificate & Test Report
      • Harmonic Requirement: IEC10000-3-2 & IEC10000-3-3 Class "D"
    • Warranty: Two (2) years manufacture's warranty.
Certificate:
  • UL
  • TUV
  • CB
  • CE

Model Number Dimension (L x W x H) Output Wattage Option+5v +3.3V +12V -12V +5VSB +5V, +3.3V Output
PRT3251U-S5 253 x 81 x 40 325W 26A 18A 20A 0.5A 0A - 2A 26A
PRT3251U-S2 253 x 81 x 40 325W 26A - 20A - - -
PRT3501U-S5 253 x 81 x 40 350W 32A 20A 23A 0.5A 0A - 2A 33A
PRT3751U-S5 253 x 81 x 40 375W 32A 20A 26A 0.5A 0A - 2A 33A
PRT4001U-S5 253 x 81 x 40 400W 32A 20A 26A 0.5A 0A-2A 33A
PRT4001U-S2 253 x 81 x 40 400W 32A - 26A - - -
PRT3251U-H5 288 x 162 x 42.5 325W 26A 18A 20A 0.5A 0A-2A 26A
PRT3251U-H2 288 x 162 x 42.5 325W 26A - 20A - - -
PRT3501U-H5 288 x 162 x 42.5 350W 32A 20A 23A 0.5A 0A-2A 33A
PRT4001U-H5 288 x 162 x 42.5 400W 32A 20A 26A 0.5A 0A-2A 33A
PRT4001U-H2 288 x 162 x 42.5 400W 32A - 26A - - -
PRT6001U-H5 288 x 270 x 42.5 600W 50A 36A 40A 0.5A 0A-2A 65A
PRT6001U-H2 288 x 270 x 42.5 600W 50A - 40A - - -
PRT6501U-H5 288 x 270 x 42.5 650W 50A 38A 46A 0.5A 0A-2A 65A
PRT7001U-H5 288 x 270 x 42.5 700W 50A 40A 52A 0.5A 0A-2A 65A
PRT7501U-H2 288 x 270 x 42.5 750W 60A - 52A - - -
PRT7501U-H5 288 x 270 x 42.5 750W 50A 40A 52A 0.5A 0A-2A 65A

Main Products:
Redundant Power Supply, Open Frame Power Supply, ATX Power Supply, AC/DC Power Supply, 1U Power Supply

Send an inquiry

Contact Details

CEO: Mr. Jason Pan
Minimum Order:Negotiable
Address:No. 693, Jhongjheng Rd., Shulin City Taipei County, 238 Taiwan
Tel:886-2-26882181
Fax:886-2-26882189