AC/DC Power Supply 2U Redundant (New)
Product ID: PRTxxx2U-Vx
2U Redundant (New Version)
This is new 2U Redundant power supply of PRT which presented in July 2006, and the series has promoted importance in 2008 by PRT.
Its wattage is from 325 ~ 400W.
- Input Voltage: 90Vac to 264Vac, with active power factor, PF=90% min.
- Input Frequency: 47 ~ 63Hz
- Input Leakage Current:
- Input leakage current from line to frame ground will be less than 3.5mA rms. foreach power module.
- Condition: 264Vac / 60Hz
- Overshoot: Any output overshoots at TURN-ON shall not exceed 10% (+5V / +12V output) and 10% (-12V/ output) of nominal voltage value.
- Hold-Up Time: Unit shall continue to supply regulated DC outputs and power good signal for at least 16 Milliseconds at 115/230Vac full load after a loss of AC input voltage which shall be represented by a short circuit at the AC input.
- Over Power Protection:
- CONDITION: Nominal input
- LIMITS: When output power is over to 120% ~ 150%
- Over Voltage Protection:
- +5VDC
- CONDITION: All operating
- LIMITS: +5.7V ~ 6.7Vdc
- +3.3VDC
- CONDITION: All operating
- LIMITS: +3.7V ~ 4.7Vdc
- +12VDC
- CONDITION: All operating
- LIMITS: +Max. 13.0V ~ 15.0Vdc
- Short Circuit Protection:
- Short circuit placed on +3.3V / +5V / +12V / -12V output shall cause no damage to this unit.
- The power supply shall be shut down.
- AUTO-RECOVERED: 5VSB.
- Efficiency: 65% min. at full load test.
- Environmental: Temperature
- Operating: 50 to 122°F (10 to 40°C). De-rate Linearly to 50% at 70°C
- Non-Operating: -4.0 to 140°F (-20 to 60°C)
- Environmental: Relative Humidity
- Operating: 20 to 90 % non-condensing at 104°F (40°C)
- Non-Operating: 10 to 90 % non-condensing at 104°F (40°C)
- RFI/EMI Standards:
- FCC part 15, Subpart B, Class B computing device.
- CISPR22 (EN55022) Class B.
- VCCI Class 2.
- Safety Standard:
- UL 60950-1
- C-UL
- UV Certification to IEC950 1 edition, and EN60950.
- CE Certificate & Test Report
- Harmonic Requirement: IEC10000-3-2 & IEC10000-3-3 Class "D".
- Dimension (L x W x H): 288 x 84 x 101 (mm)
- Warranty: Two (2) years manufacture's warranty.
- UL
- TUV
- CB
- CE
| Model Number | Total AC Input | Option +5v | +3.3V | +12V | -12V | +5VSB | +5V, +3.3V Output | Output Wattage |
|---|---|---|---|---|---|---|---|---|
| PRT3252U-V5 | 100-240 ~ 5.0A50/60Hz | 26A | 18A | 20A | 0.5A | 0A - 2A | 26A | 325W |
| PRT3252U-V2 | 100-240 ~ 5.0A50/60Hz | 26A | - | 20A | - | - | Total: 325W | 325W |
| PRT3502U-V5 | 100-240 ~ 5.0A50/60Hz | 32A | 20A | 23A | 0.5A | 0A - 2A | 33A | 350W |
| PRT3752U-V5 | 100-240 ~ 6.3A50/60Hz | 32A | 20A | 26A | 0.5A | 0A - 2A | 33A | 375W |
| PRT4002U-V2 | 100-240 ~ 6.3A50/60Hz | 32A | - | 26A | - | - | Total: 400w | 400W |
| PRT4002U-V5 | 100-240 ~ 6.3A50/60Hz | 32A | 20A | 26A | 0.5A | 0A - 2A | Total: 400w | 400W |
Main Products:
Redundant Power Supply, Open Frame Power Supply, ATX Power Supply, AC/DC Power Supply, 1U Power Supply
Related Products
Contact Details
CEO: Mr. Jason Pan
Minimum Order:Negotiable
Address:No. 693, Jhongjheng Rd., Shulin City Taipei County, 238 Taiwan
Tel:886-2-26882181
Fax:886-2-26882189
E-mail:
service@prt.com.tw




