TECPEL Co., Ltd.

Send an inquiry
Differential Probe 25MHz/ 100MHz

Product ID: HP-25, HP-100

Differential Probe 25MHz/ 100MHz

25MHz Differential Probe

product pic

100MHz Differential Probes

25 MHz Differential Probe Model: HP-025

1. Make floating measurements simply and safety

2. Compatible with analog or digital storage oscilloscope
3. In compliance with IEC-1010.1, IEC-1010.2-031 CAT III , Pollution
degree 2

100MHz HP-100 Differential Probe
1.Bandwidth DC to 100MHz (-3dB)
2. Input Impedance 4MΩ//7pF Accuracy +/- 2%
3. Attenuation Ratio 1/100& 1/1000
4. Input Voltage : +/- 140V(DC+Peak AC) or 100Vrms for 1/100

----------------------------------------
TECPEL CO., LTD
NO, 13, ALLEY 5, LANE 31 CHUNG-TEH STREET,
TAIPEI 110, TAIWAN, R.O.C.
E-MAIL: sales@tecpel.com Web-site: http://www.tecpel.com
TEL:2-27375866 FAX:886-2-27373343

Specifications:
  • 25 MHz HP-025 Differential Probe
    • Bandwidth : DC to 25MHz (-3dB)
    • Attenuation Ratio : 1/20 & 1/200
    • Accuracy : +2%
    • Input Impedance : 4MΩ / 10pF each side to ground
    • Differential Input Range : +1400V(DC+AC peak) or 1000V rms for 1/200
    • +140V(DC+AC peak) or 100V rms for 1/200
    • Common Mode Range : +1400V(DC+AC peak) or 1000V rms
    • Output Offset : <+5mV, -10℃ to 40℃
    • Cable length : 95cm (RG58/U)
    • Power Requirements : 4x AA cels or 6VDC/60mA mains adapter (not supplied)
    • Dimension : 6.6" x 2.4" x 0.8" (168x62x20mm)
    • Weight : 285gms (0.583 lbs)
  • 100MHz HP-100 Differential Probe
    • HP-100
    • Bandwidth DC to 100MHz (-3dB)
    • Input Impedance 4MΩ//7pF
    • Accuracy +/- 2%
    • Attenuation Ratio 1/100& 1/1000
    • Input Voltage : +/- 140V(DC+Peak AC) or 100Vrms for 1/100
    • Max Differential:+/- 1400V(DC+Peak AC) or 1000Vrms for 1/1000
    • -Max. Common Mode: +/- 1400V(DC+Peak AC) or 1000Vrms for 1/100 & 1/000
    • -Absolute Max. +/- 1400V(DC+Peak AC) or 1000Vrms for 1/1000 Output Voltage
    • -Max. Amplitude +/- 1.4V (into 50Ω load)
    • -Offset (typical) < +/- 5mV, -10 to 40 Centigrade
    • -Noise (typical) 0.6mVrms
    • CMRR
    • -60Hz/1MHz 80dB/50dB
    • Power Requirements 4 x AA cells or 6VDC/200mA mains adapter
    • Weight 800gms
    • Dimensions (LxWxH) 207mm x83mmx38mm
    • Compliance IEC-1010 CAT Ⅲ
Certificate:
  • CE