High Voltage Test Probe Model¡GHV-40 Features : Connect to any digital multimeter with industry standard jacks to measure up to 40K VDC or peak AC or 28KV rms AC. ----------------------------------------- HVP-40M Features: DC 40KV CAT II Pollution 2 600M Ohm Impedance 25KV ¡Ó 2%, 40KV ¡Ó 3% T.C. 200 ppm/°C. Positive Polarity only. Resolution 1KV No Need power. CE, TUV GS, UL, CUL, IEC1010
Specifications:
- HV-40 SPECIFICATION:
- Max. Working Voltage : 40kV DC or Peak AC 28kV rms AC
- Accuracy : DC Volts : +1%(1kV to 20kV); +2%(20kV to 40kV)
- AC Volts : Typically 5% at 60Hz
- Division Ratio : 1000 : 1
- Input Resistance : Approx. 1000M Ohm
- Cable length : 1 meter ¡@
- TECPEL CO., LTD
- E-MAIL: sales@tecpel.com Web-site: http://www.tecpel.com
- TEL:2-27375866 FAX:886-2-27373343
- HVP-40M
- SPECIFICATIONS ( 20 ± 5°C, RH < 80% )
- ! WARNING !
- Before taking any measurements, first connect the alligator clip of this probe to earth ground and make sure connection is electrically good.
- Input impedance:600M Ohm
- Maximum operation voltage:40KV DC , CAT II , Pollution 2
- Polarity:Positive only
- Display:Analog indicate
- Accuracy:Factory calibrater 25KV ± 2%
- FULL scale 40KV ± 3 %
- Temperature Coefficient:<= 200ppm / °C.
- Maximum loading Current:<=70 µA
- Maximum loading power:<= 3 watt
- Voltage Range:40KV / 1 Range
- Voltage resolution:1KV
- Power source:Need not power
- Operating temperature:0 °C ~ + 50 °C.
- Storage temperature:- 20 °C ~ + 70 °C.
- Ground lead length:90cm ( 35 " )
- Dimensions:420 L x 80 ø
- Weight:360g
- Minimum Order: Negotiable
- TEL: 886-2-27375866
- FAX: 886-2-27373343
- E-mail: sales@tecpel.com, tecpel@seed.net.tw
Certificate:
CE_UL_TUV