Specifications:
- Items: Contact resistance
- Test Conditions:
- Include the pattern resistance.
- Measured by a voltage drop method at 5v DC, 1A.
- Criteria: 100m Ω or less
- Items: Insulation resistance
- Test Conditions: 250V DC applied between terminals for 1 min ±5sec
- Criteria: 500m Ω or less
- Items: Insulation resistance
- Test Conditions: 500V DC applied between the terminal and the frame for 1 min ±5sec
- Criteria: 5,000m Ω or less
- Items: Withstand Voltage
- Test Conditions:
- 250V AC applied between terminals 1 min ±5sec
- AC 1,500V applied between the terminal and the frame for 1 min ±5sec
- Criteria: No dielectric break down shall occur.
- Items: Tolerance Voltage and current
- Test Conditions: Resistive load
- AC: 50V, 5V / 0.05A, 0.5A
- DC: 25V, 5V / 0.05A, 0.25A
- Oil proof, water proof, completely sealed construction. Using a special rubber O ring that is oil and water proof.
- Labor saving with minimum wiring. Wiring that has been 60 in the past is now 7, and connector connection is also OK.
- Gold contact (double contacts) with high reliability.
- Various generalized wide codes.
- Changeover angle 15° / 0 ~ 23 positions
- Changeover angle 30° / 0 ~ 11 positions
- Other gray codes etc. special codes and 26 contact
- 0 ~ 25 position custom also possible.
- Inhibit to prevent error (mute), with a newly established parity circuit.
- Stopper position change is unrestricted. Position can be changed with one touch through the self tapping insertion of the screw.
- Solidity: Stopper strength 30kgf.cm
- Longevity: Contact frequency 2,000,000 steps.
- Minimum Order: Negotiable