Applications: For the electronic measurement of voltages: AC, DC IMPL., etc., with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits. Main Technical Data: 1. Primary normal voltage VPN: 1000V r.m.s 2. Primary voltage, measuring range VP: 0~+/-1500V 3. Primary normal current IPN: 5mA r.m.s 4. Measuring resistance: RMmin RMmax with +/-15V @ +/-1000V max: 0 ohm ~ 200 ohm @ +/-1500V max: 0 ohm ~ 70 ohm 5. Secondary normal current: 50mA rms 6. Conversion ratio: 1000V/50mA 7. Supply voltage(+/-5%): +/-15V 8. Current consumption: 15mA + Secondary output current 9. Isolation test: Between the primary circuit (+HT.-HT) and the secondary circuit(+.-.M): 7kVrms/50Hz/1min Between the secondary circuit (+.-.M) and the shield(E): 1kVrms/50Hz/1min Accuracy - Dynamic Performance Data: 1. Accuracy @ VPN, TA=+25°C: +/-1% 2. Non-linearity @ VPN, TA=+25 °C: better than +/-0.1% 3. Offset current @ IP=0, TA=+25°C: not more than +/-0.3mA 4. Thermal drift: +/-0.6mA(0°C ~+80 °C) 5. Response time @90% of VPmax: not more than 70us General Data: 1. Operating temperature: 0°C ~ +80°C 2. Storage temperature: -25 °C ~ +85°C 3. Turns ratio: 20000:2000 4. Total primary power loss: 5W 5. Primary resistance @ TA=+25 °C: 200 kilohm 6. Secondary coil resistance: not more than 60 ohm 7. Weight: 850g 8. Standards: EN 50178
Specifications:
Features:
- Hall effect measuring principle.
- Galvanic isolation between primary and secondary circuit.
- Insulated plastic case made of black PPO recognized according to UL 94-V0.
Certificate:
ISO 9001, ISO 14001
Ordering information:
- Minimum Order: Negotiable
- TEL: 86-574-8738 3998
- FAX: 86-574-8735 9851
- E-mail: sarah-chen@zelrinb.com.cn