Taiwan Superior Electric Co., Ltd.

Send an inquiry
Electronics Relay

Product ID: SRUT

Electronics Relay

Application, Remote Control TV Receivers, Monitor Displays, Audio Equipment, High Rushing Current Use Application

Specifications:
  • Contact rating:
    • Rated load: AC 120V, TV-5 (incandescent lamp 5A); AC 240V, 5A (rush current 80A)
    • Maximum carrying current: 5A
    • Maximum allowable voltage: AC 240V/DC 110V
    • Maximum allowable current: 5A
    • Maximum allowable power force: 600VA, 300W
    • Minimum load (ref. Value): DC 5V 100mA
    • Contact material: Ag-Alloy
  • Performance (at initial value)
    • Contract resistance: 100mΩ max.
    • Operate time: 15msec max.
    • Release time: 5msec max.
    • Dielectric strength: between coil & contact is AC 1500V 50/60 Hz (1 min); between contacts is AC 750V 50/60 Hz (1 min.)
    • Surge resistiveness: 3000V (between coil and contact 1.2 x 50 mA sec.)
    • Insulation resistance: 100mΩ min. (500V DC)
    • Max. on/off switching mechanically and electrically: 300 operations/min.; 30 operations/min.
    • Operating ambient temperature: -30 ℃ to + 60 ℃ (no condensation of water drop)
    • Operating humidity: 45% to 85% RH
    • Coil temperature rise: 35 deg Max. (at rated coil voltage)
    • Endurance and error operation: 10 to 55Hz dual amplitude width 1.5mm; 10 to 55Hz dual amplitude width 1.5mm
    • Shock endurance and error operation: 100G min; 10G min.
    • Life expectancy mechanically and electrically: 10,000,000 operations min; 100,000 operations min.
    • Weight: abt.12g
    • UL file no.: E82292 (TV-5)
    • CSA file no.: LR48471 (TV-5)
Features:
  • Conforming to UL, CSA, JA.M.C.L
  • Employment of suitable plastic material to be to high temperature and various chemical solution.
  • Complete sealed type available if require.

Coil sensitivity (at20 Celsius) Coil voltage code (at20 Celsius) Nominal voltage code (VDC) (at 20 Celsius) Nominal current (mA) (at 20 Celsius) Coil resistance ohm +/- 10% (at 20 Celsius) Power consumption (W)(at 20 Celsius) Pull-in voltage (VDC) (at 20 Celsius) Drop-out voltage (VDC) (at 20 Celsius) Max-allowable voltage (VDC) (at 20 Celsius)
SRUT TV-5 03 3 120 25 Abt. 0.36 75% max .5% min .130%
SRUT TV-5 06 6 60 100 Abt. 0.36 75% max .5% min .130%
SRUT TV-5 09 9 40 225 Abt. 0.36 75% max .5% min .130%
SRUT TV-5 12 12 30 400 Abt. 0.36 75% max .5% min .130%
SRUT TV-5 24 24 15 1,600 Abt. 0.36 75% max .5% min .130%
SRUT TV-5 48 48 10 4500 Abt. 0.66 80% max .5% min .130%

Main Products:
general purpose relays, automotive relays, telecom relays, solid state input / output modules, time delay relays, circuit breakers

Send an inquiry