Starmen Opto-Electronic Co. Ltd.

Send an inquiry
Combo For LCD Monitor / TV Build In

Product ID: Combo For LCD Monito

Combo For LCD Monitor / TV Build In

Specifications:
POWER GENERAL SPEC.
* Universal Input Voltage 90 to 264VAC
* Power Saving < 1Watt (standby no load)
* Efficiency: 80% tyical at full load
* Hold- up time: 8 msec at full load, 115V/230V
* Inrush current: Internally limited by thermistor 30A/115 VAC; 60A/230 VAC
* Operating temperature: Full rating 0 ~ 40C Degree
* Storage temperature: -40 ~ +70C Degree
* MTBF: 50,000 hours min. Per MIL-HDBK-217E
* Hi-Pot: 1,500VAC 1Sec. (P. to S.) for class I
* Low Ripple & Noise 1% Max. (output voltage)
* Short Circuit & Temperature Protection
* EMI requirements: Meets
a) FCC Class B
b) VCCI Class B
c) CISPR Class B
* Safety requirements: Meets
a) UL 60950 & UL 6500
b) cUL CSA 22.2 No.60950 & E60065
c) TUV EN60950 & EN60065
d) CCC GB4943 & GB8898
e) CB IEC60950 & IEC60065

INVERTER GENERAL SPEC.
* Operating Temperature: 0 ~ 40C Degree
* Storage Temperature: 0 ~ 60C Degree
* Operating Humidity: 8 ~ 80%RH, Without dewdrop
* Storage Humidity: 5 ~ 90%RH, Without dewdrop
* Conditions at 25C Degree ambient unless otherwise spec.
* All products ZAULaS applications in use

Specifications:
  • General^$This specification defines the performance characteristics of ClassⅠ, AC/DC + DC/AC POWER BOARD. This specification also defines the worldwide safety requirements and EMC requirements.^#Input Characteristics (AC / DC POWE^$a. AC Input Voltage
  • The power supply will operate over the entire input voltage range (90-264VAC).
  • b. Frequency
  • The input frequency range will be 47Hz to 63 Hz.
  • c. Input Current
  • The input current will not exceed 1.6Amp(rms.) for 90 VAC.
  • d. Efficiency
  • The power supply efficiency (watts output/watts input) will not be less than 78% typically at full load 115 VAC /60Hz condition.
  • e. Hold Up Time
  • The output hold up time (measured at the 90% point of normal voltage output) will be guaranteed 8msec at test condition which is full load,115 VAC /60Hz, normally line, 25℃ ambient temperature.^#Output Characteristics^$a. DC Load Characteristics
  • The power supply output voltage is 11.4Vmin~12.6Vmax at 0~3.5Amps load.
  • The power supply accepts tolerance that is 4.0Amps ?.5Amps overload.
  • b. Ripple & Noise
  • The power supply ripple & noise will be less than 120mV.Note: A0.1μF Ceramic and 10μF Tantalum capacitors should be put across output terminals during ripple & noise test. The oscilloscope bandwidth is set at 20MHz and co-axial probe will be used to measure it. The test condition is max. load and normally line.
  • c. Overshoot
  • The power supply use in overshoot at turn on or turn off AC input will be less than 10% of the nominal value and will decay itself within the regulation band in less than 50m sec.^#Protection^$a. Primary (Input) Protection
  • The input power line will be fused with a fuse 2.0A, 250 VAC.
  • b. Secondary (Output) protection
  • b.1. Over Current Protection
  • When an internal fault occurs, or an external fault is applied to the power supply, such that an overload or short circuit is applied to the output, the power supply will be shutdown. power supply latch is not allowed.
  • b.2 Over Voltage Protection
  • If an over-voltage fault occurs on the power supply output, the power supply will shutdown before the output exceeds 16.0V. All of power supply shutdown.
  • b.3 Short Circuit Protection
  • The power supply will protect itself, and shut down, if a short circuit is placed between DC return and the output. This condition will cause no damage to the power supply . Power supply latch is not allowed.^#Power Supply Sequencing^$a.. AC Power On
  • When proper AC power is applied, the output will reach its regulation limits within 2.0 second at 110 VAC.
  • b. Output Rise Time
  • The output rise time (measured from the 10% point to the 90% point on the waveform) will be greater than 1m sec and less than 20m sec.^#
  • Features:
  • Universal Input Voltage 90 to 264VA^$* Universal Input Voltage 90 to 264VAC
  • * Power Saving < 1Watt (standby no load)
  • * Efficiency: 80% tyical at full load
  • * Hold- up time: 8 msec at full load, 115V/230V
  • * Inrush current: Internally limited by thermistor 30A/115 VAC; 60A/230 VAC
  • * Operating temperature: Full rating 0 ~ 40C Degree
  • * Storage temperature: -40 ~ +70C Degree
  • * MTBF: 50,000 hours min. Per MIL-HDBK-217E
  • * Hi-Pot: 1,500VAC 1Sec. (P. to S.) for class I
  • * Low Ripple & Noise 1% Max. (output voltage)
  • * Short Circuit & Temperature Protection
  • * EMI requirements: Meets
  • a) FCC Class B
  • b) VCCI Class B
  • c) CISPR Class B
  • * Safety requirements: Meets
  • a) UL 60950 & UL 6500
  • b) cUL CSA 22.2 No.60950 & E60065
  • c) TUV EN60950 & EN60065
  • d) CCC GB4943 & GB8898
  • e) CB IEC60950 & IEC60065 ^#E.M.I.^$a. Conduction
  • The power supply will conform to FCC Class B, VCCI Class B, and CISPR Class B.
  • b. Radiation
  • The power supply will conform to FCC Class B, VCCI Class B, and CISPR Class B.^#Safety Characteristics^$a. Safety Meet Requirements
  • UL : UL60950 Third Edition & UL6500
  • cUL :: CSA 22.2 No.60950 & E60065
  • TUV : EN60950 & EN60065
  • CCC : GB4943 & GB8898
  • CB : IEC60950 & IEC60065
  • b. Withstand Voltage
  • Primary to secondary : 1500 VAC 10mA for 3 seconds.
  • c. Provisions for Protective Earthling
  • While 12V/25A applied on between primary and secondary side together and provisions for protective earthling is less than 0.1 ohm for 3 seconds.
  • d. Inrush Current
  • The power supply inrush current is less than 60Amps(peak to peak) at the time of cold start at 230 VAC Condition.^#Environment^$a. Operating
  • The power supply operating temperature is 0℃ to 40℃.
  • The power supply operating relative humidity is 20% to 85%.
  • b. Storage
  • The power supply storage temperature is -40℃ to 70℃.
  • The power supply storage relative humidity is 10% to 95%.^#Life^$a. On - off Life
  • To verify the power supply withstand 10,000 time on-off repetition of primary power Without failure or damage at 230 VAC input.
  • b. Operational life
  • The power supply will be designed for a minimum life of 100,000 power-on hours at 25℃ Ambient temperature, at full load condition. ^#
  • Certificate:
    • EMI
    • UL
    • FCC
    • TUV
    • CB


    Main Products:
    switching power supply adapter, open frame

    Send an inquiry