¡¶ JHM-2028 main technical parameter ¡» Volume (length¡Ñ width ¡Ñheight): •370mm¡Ñ340mm ¡Ñ1570mm ¡» Weight: about 90kg ¡@¡@ ¡» Power supply voltage: AC220V¡Ó10% ¡@¡@ •Frequency: 50HZ ~ 60 HZ •Power: 1500W ¡» Blood pump/spare pump: •Flux: 15 ~ 340ml/min (Ф 6mm) 20 ~ 460 ml/min (Ф 8mm) ¡» Heparin pump: •Flux: 0.1ml/h¡ã10ml/h(¡Ó5%) •Precise: 0.1ml/h •Injector size: 20ml/30ml/50ml 10ml/20ml/30ml (selectable) ¡» Arterial pressure: •display scope:-300mmHg¡ã+300mmHg (¡Ó10mmHg) ¡» Venous pressure: •display scope:-50mmHg¡ã+300mmHg (¡Ó10mmHg) ¡» Dialysate flow: •300ml/min¡ã800ml/min linearity adjustable (+10%) (-5%) •Temperature:35.0¢J~39.0¢J •Resolving rate:0.1¢J •Conductivity:13mS/cm~15.5mS/cm (¡Ó0.1 mS/cm) ¡» UF flow scope: 0¡ã1800ml/h(¡Ó30ml/h ) 0¡ã4000ml/h(optional) ¡» ISO UF flow scope:0¡ã2000ml/h(¡Ó30ml/h) ¡» TMP •Scope:-100mmHg¡ã+600mmHg (¡Ó20mmHg) ¡» Blood leakage monitor: •over 1ml blood per liter dialysate (flow:500ml/min) ¡» Blood level monitor: ultrasonic sensor ¡» Air bubble monitor: •Infrared and response threshold value: Single air bubble of 200 и I exists when Blood flux is 200ml/min ¡» Inflow pressure:0MPa¡ã0.6MPa ¡» Inflow temperature: 5¢J¡ã30¢J ¡» Environment temperature: 10¢J¡ã30¢J, • Relative humidity≤70% ¡» Rinse/disinfection: chemical disinfection (citric acid,peracetic acid and oxalic acid) ¡» Hot rinse: 80¢J ¡» Back-up power supply: last for 15-30min after electric-cut.(optional) ¡¶ JHM-2028 function Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.Touch screen was equipped and it can show Na¡Ïand UF profiles;In addition,the functions ie.backup power supply, Kt/V,HCO3£¼ adjustment,single needle and acetate treatment are optional. ¡¶ Clinical Application ¡» Hemodialysis Therapy:same as JH-2000 ¡» Pure ultrafiltration Therapy: same as JH-2000 ¡» Hemoperfusion Therapy:same as JH-2000 ¡» Plasma exchange Therapy:same as JH-2000 ¡» Na¡Ïand UF profiling: •Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect. ¡» Kt/V function: •The sufficiency of dialysis can be reflected by Kt/V.(Optional) ¡» HCO3 adjustment function: •Be applicable for sericous acid toxicosis patient. Be capable to calibrate the acid toxicosis status according to patient's state of illness.(optional) ¡» Backup power-supply: •It can last for 15-30 minutes after power cut off.(Optional) Providing the programmed UF and adjustable Na+ dialysis(Totally there are seven Na+ curves and seven Ufcurves for your selection). The suitable curve can be selected basing on patien's actual status. Kt/V onsite test Profilling
Specifications:
Ordering information:
- Minimum Order: 10pcs set
- TEL: 86-571-85194485
- FAX: 86-571-56832739
- E-mail: tom181898@gmail.com