FLRY-B

Product ID: Thin Wall, with Conductor (Type B)

Send Inquiry
Nominal Cross Section Conductor Conductor Conductor Conductor Insulation Insulation Overall Diameter (max.)
- No. of Strands Diameter of Strand Outer Diameter Electric Resistance at 20°C (max.) Nominal Wall Thickness Min. Wall Thickness -
mm² - mm mm mΩ/m mm mm mm
0.35 12 0.20 0.8 54.40 0.25 0.20 1.4
0.50 16 0.20 1.0 37.10 0.28 0.22 1.7
0.75 24 0.20 1.2 24.70 0.30 0.24 1.9
1.00 32 0.20 1.3 18.50 0.30 0.24 2.1
1.50 30 0.25 1.6 12.70 0.30 0.24 2.4
2.00 30 0.30 1.9 9.42 0.35 0.28 2.8
2.50 50 0.25 2.1 7.60 0.35 0.28 3.0
3.00 19 0.45 2.3 6.10 0.4 0.32 3.4
4.00 56 0.30 2.6 4.71 0.40 0.32 3.8
6.00 84 0.30 3.2 3.14 0.40 0.32 4.3
Features
  • Application :
    • Low-tension wires with thin wall insulation for automobiles, motorcycles and other motor vehicles. ISO 6722 compliant.
  • Materials/Standard :
    • Conductor : Soft-annealed copper wires in compliance with ISO 6722
    • Insulation : Vinyl (PVC) insulated. In compliance with ISO 6722 and RoHS Directive.
  • Temperature rate :
    • -40°C ~ +105°C

Main Products

Halogen Free Thin-Wall Cable, Halogen Free Ultra Thin-Wall Cable, Thin-wall cable, Cable, Wire

Contact Detail