Features
- Operating speed: 0.01mm to 1m/sec.
- Operating frequency:
- Mechanically: 240 operations/min.
- Electrically: 20 operations/min.
- Contact resistance: 15m ohm(s) max.(initial).
- Insulation resistance: 100M ohm(s) min.(at 500VDC).
- Service life:
- Mechanically: 20,000,000 operations min.
- Electrically: 500,000 operations min.
- Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7msec. Max.(DC).
- Lamp load has an inrush current of 10 times the steady-state current, while motor load has an inrush current of 6 times the steady-state current.
Rated voltage(V) | Non-inductive load(A), resistive load, NC | Non-inductive load(A), resistive load, ND | Non-inductive load(A), lamp load, NC | Non-inductive load(A), lamp load, ND | Inductive load(A), inductive load, NC | Inductive load(A), inductive load, ND | Inductive load(A), motor load, NC | Inductive load(A), motor load, ND | Inrush current(A), NC | Inrush current(A), ND |
---|---|---|---|---|---|---|---|---|---|---|
125VAC | 15 | 15 | 3 | 1.5 | 15 | 15 | 5 | 2.5 | 30 max. | 15 max. |
250VAC | 15 | 15 | 2.5 | 1.25 | 15 | 15 | 3 | 1.5 | 30 max. | 15 max. |
500VAC | 3 | 3 | 1.5 | 0.75 | 2.5 | 2.5 | 1.5 | 0.75 | 30 max. | 15 max. |
8VDC | 15 | 15 | 3 | 1.5 | 15 | 15 | 5 | 2.5 | 30 max. | 15 max. |
14VDC | 15 | 15 | 3 | 1.5 | 10 | 10 | 5 | 2.5 | 30 max. | 15 max. |
30VDC | 6(2) | 6(2) | 3 | 1.5 | 5 | 5 | 5 | 2.5 | 30 max. | 15 max. |
125VDC | 0.4 | 0.4 | 0.4 | 0.4 | 0.05 | 0.05 | 0.05 | 0.05 | 30 max. | 15 max. |
Main Products
contactors, magnetic switches, thermal overload relays timer, limit switches, control components