Our Advantages:
1. With automatic production in 24 hours
2. With the ability to produce 1.5 million meters per day.
3. With good reputation and numerous customers both at home and overseas
4. With good quality ,strict QC inspection and reasonal price.
5 Wire manufacture provides OEM, welcome to give us more details or sample, we will try our best to customize the wire as buys’ requests. By the way, we could provide free sample client require in some circumstance.
Quick details:
Place of Origin Foshan, China (Mainland)
Brand Name Mingda or as client’s request
Type Insulated
Application Arrangement of wire
Conductor Material Copper or AL
Conductor Type Standard
Insulation Material PVC (Polyvinyl-Chloride)
Production Standard 3C、CE
Packaging & Delivery
Packaging Details: Export package standard or according to customers requirement
Delivery Detail: 20~25 days after receiving 30% T/T
Payment term:
Our payment term is 30% deposit in advance, 70% rest against copy of B/L; or 100% irrevocable L/C at sight
RV
Copper conductor PVC insulated flexible connector cable (electrical wire)
1)PVC Copper Insulation Electrical Cable with Voltage of 300/500V
2.)1.5mm, 2mm, 4mm, 6mm
1.Rated temperature105oC
2.Rated voltage300V
3.Reference standardUL758,UL1581,CSA C22.2No.210.2
4.Solid or stranded ,tinned or bare copper conductor
5.PVC insulation , comply with ROHS environmental standard
6.PVC covering , comply with ROHS environmental standard
7.Passes UL VW-1,CSA FT1 and JQA F-Mark flame test
8.Uniform insulation thickness to ensure easy stripping and cutting
9.For general purpose internal wiring of appliance
227IEC 02(RV)
Flexible Electric Wire
Rating:450/750V 70℃
Standard:GB5023
Normal area Conductor construction Insulation thickness Overall diameter Max conductor resistance at 20℃
(MM2) No/mm (MM) (MM) Solid Stranded
1.5 30/0.25 0.7 3.10±0.1 13.3 13.7
2.5 49/0.25 0.8 3.80±0.1 7.98 8.21
4.0 56/0.30 0.8 4.20±0.1 4.95 5.09
6.0 84/0.30 0.8 5.30±0.1 3.30 3.39
227IEC 06(RV)
Flexible Electric Wire
Rating:300/500V 70℃
Standard:GB5023
Normal area Conductor construction Insulation thickness Overall diameter Max conductor resistance at 20℃
(MM2) No/mm (MM) (MM) Solid Stranded
0.5 16/0.2 0.6 2.20±0.1 39.0 40.1
0.75 24/0.2 0.6 2.40±0.1 26.0 26.7
1.0 32/0.2 0.6 2.55±0.1 19.5 20.0
227IEC 08(RV-90)
Flexible Electric Wire
Rating:300/500V 90℃
Standard:GB5023
Normal area Conductor construction Insulation thickness Overall diameter Max conductor resistance at 20℃
(MM2) No/mm (MM) (MM) Solid Stranded
0.5 16/0.20 0.6 2.20±0.1 39.0 40.1
0.75 24/0.20 0.6 2.40±0.1 26.0 26.7
1.0 32/0.2 0.6 2.55±0.1 19.5 20.0
1.5 30/0.25 0.7 3.15±0.1 13.3 13.7
2.5 49/0.25 0.8 3.70±0.1 7.98 8.21
RVV
Copper conductor PVC insulated PVC sheathed round flexible connector cable (electrical wire)
1.Conductor: Multi-Unit bare copper wire strands
2.Insulation: polyvinyl chloride (PVC)
3.Sheath: Polyvinyl Chloride (PVC)
4.Rated Voltage: UO / U for 300/500 V
5.Temperature Rating: long-term temperature should be no more than 70
2271EC 52(RVV)
Rating: 300/300V 70℃
Standard: GB5023
NO.of conductor Normal area Construction Insulation thickness Sheath Thickness Overall diameter Max conductor resistance at 20℃(Solid Stranded)
2 0.5 16/0.20 0.5 0.6 5.1±0.1 39.0 40.1
2 0.5 16/0.20 0.5 0.6 3.2±0.1*5.2±0.1 39.0 40.1
2 0.75 24/0.20 0.5 0.6 5.6±0.1 26.0 26.7
2 0.75 24/0.20 0.5 0.6 3.4±0.1*5.6±0.1 26.0 26.7
3 0.5 16/0.20 0.5 0.6 5.1±0.1 39.0 40.1
3 0.75 24/0.20 0.5 0.6 5.6±0.1 26.0 26.7
227IEC 53(RVV)
Flexible Electric Wire
Rating:300/500V 70℃
Standard:GB5023
NO.of conductor Normal area Construction Insulation thickness Sheath Thickness Overall diameter Max conductor resistance at 20℃(Solid Stranded)
2 0.75 24/0.2 0.6 6.4±0.2 26.0 26.7
2 0.75 24/0.2 0.6 4.0±0.1*6.4±0.2 26 26.7
2 1.0 32/0.2 0.6 6.7±0.2 19.5 20.0
2 1.5 30/0.25 0.7 7.7±0.2 13.3 13.7
2 2.5 49/0.25 0.8 9.4±0.2 7.98 8.21
3 0.75 24/0.2 0.6 6.8±0.2 26 26.7
3 1.0 32/0.2 0.6 7.2±0.2 19.5 20.0
3 1.5 30/0.25 0.7 8.5±0.2 13.3 13.7
3 2.5 49/0.25 0.8 10.2±0.2 7.98 8.21
4 0.75 24/0.2 0.6 7.4±0.2 26 26.7
1.0 32/0.2 0.6 8.0±0.2 19.5 20.0
1.5 30/0.25 0.7 9.4±0.2 13.3 13.7
2.5 49/0.25 0.8 11.0±0.3 7.98 8.21
5 0.75 24/0.2 0.6 8.4±0.2 26 26.7
1.0 32/0.2 0.6 8.8±0.2 19.5 20.0
1.5 30/0.25 0.7 10.6±0.3 13.3 13.7
2.5 49/0.25 0.8 12.4±0.3 7.98 8.21
RVB
Copper conductor PVC insulated flat flexible connector cable (electrical wire)
Duplex electric cable
1.Conductor: Multi-Unit bare copper wire strands
2.Insulation: polyvinyl chloride (PVC)
3.Rated Voltage: UO / U for 300/300 V
4.Temperature Rating: long-term temperature should be no more than 70 degree C
……………………ETC.
1. With automatic production in 24 hours
2. With the ability to produce 1.5 million meters per day.
3. With good reputation and numerous customers both at home and overseas
4. With good quality ,strict QC inspection and reasonal price.
5 Wire manufacture provides OEM, welcome to give us more details or sample, we will try our best to customize the wire as buys’ requests. By the way, we could provide free sample client require in some circumstance.
Quick details:
Place of Origin Foshan, China (Mainland)
Brand Name Mingda or as client’s request
Type Insulated
Application Arrangement of wire
Conductor Material Copper or AL
Conductor Type Standard
Insulation Material PVC (Polyvinyl-Chloride)
Production Standard 3C、CE
Packaging & Delivery
Packaging Details: Export package standard or according to customers requirement
Delivery Detail: 20~25 days after receiving 30% T/T
Payment term:
Our payment term is 30% deposit in advance, 70% rest against copy of B/L; or 100% irrevocable L/C at sight
RV
Copper conductor PVC insulated flexible connector cable (electrical wire)
1)PVC Copper Insulation Electrical Cable with Voltage of 300/500V
2.)1.5mm, 2mm, 4mm, 6mm
1.Rated temperature105oC
2.Rated voltage300V
3.Reference standardUL758,UL1581,CSA C22.2No.210.2
4.Solid or stranded ,tinned or bare copper conductor
5.PVC insulation , comply with ROHS environmental standard
6.PVC covering , comply with ROHS environmental standard
7.Passes UL VW-1,CSA FT1 and JQA F-Mark flame test
8.Uniform insulation thickness to ensure easy stripping and cutting
9.For general purpose internal wiring of appliance
227IEC 02(RV)
Flexible Electric Wire
Rating:450/750V 70℃
Standard:GB5023
Normal area Conductor construction Insulation thickness Overall diameter Max conductor resistance at 20℃
(MM2) No/mm (MM) (MM) Solid Stranded
1.5 30/0.25 0.7 3.10±0.1 13.3 13.7
2.5 49/0.25 0.8 3.80±0.1 7.98 8.21
4.0 56/0.30 0.8 4.20±0.1 4.95 5.09
6.0 84/0.30 0.8 5.30±0.1 3.30 3.39
227IEC 06(RV)
Flexible Electric Wire
Rating:300/500V 70℃
Standard:GB5023
Normal area Conductor construction Insulation thickness Overall diameter Max conductor resistance at 20℃
(MM2) No/mm (MM) (MM) Solid Stranded
0.5 16/0.2 0.6 2.20±0.1 39.0 40.1
0.75 24/0.2 0.6 2.40±0.1 26.0 26.7
1.0 32/0.2 0.6 2.55±0.1 19.5 20.0
227IEC 08(RV-90)
Flexible Electric Wire
Rating:300/500V 90℃
Standard:GB5023
Normal area Conductor construction Insulation thickness Overall diameter Max conductor resistance at 20℃
(MM2) No/mm (MM) (MM) Solid Stranded
0.5 16/0.20 0.6 2.20±0.1 39.0 40.1
0.75 24/0.20 0.6 2.40±0.1 26.0 26.7
1.0 32/0.2 0.6 2.55±0.1 19.5 20.0
1.5 30/0.25 0.7 3.15±0.1 13.3 13.7
2.5 49/0.25 0.8 3.70±0.1 7.98 8.21
RVV
Copper conductor PVC insulated PVC sheathed round flexible connector cable (electrical wire)
1.Conductor: Multi-Unit bare copper wire strands
2.Insulation: polyvinyl chloride (PVC)
3.Sheath: Polyvinyl Chloride (PVC)
4.Rated Voltage: UO / U for 300/500 V
5.Temperature Rating: long-term temperature should be no more than 70
2271EC 52(RVV)
Rating: 300/300V 70℃
Standard: GB5023
NO.of conductor Normal area Construction Insulation thickness Sheath Thickness Overall diameter Max conductor resistance at 20℃(Solid Stranded)
2 0.5 16/0.20 0.5 0.6 5.1±0.1 39.0 40.1
2 0.5 16/0.20 0.5 0.6 3.2±0.1*5.2±0.1 39.0 40.1
2 0.75 24/0.20 0.5 0.6 5.6±0.1 26.0 26.7
2 0.75 24/0.20 0.5 0.6 3.4±0.1*5.6±0.1 26.0 26.7
3 0.5 16/0.20 0.5 0.6 5.1±0.1 39.0 40.1
3 0.75 24/0.20 0.5 0.6 5.6±0.1 26.0 26.7
227IEC 53(RVV)
Flexible Electric Wire
Rating:300/500V 70℃
Standard:GB5023
NO.of conductor Normal area Construction Insulation thickness Sheath Thickness Overall diameter Max conductor resistance at 20℃(Solid Stranded)
2 0.75 24/0.2 0.6 6.4±0.2 26.0 26.7
2 0.75 24/0.2 0.6 4.0±0.1*6.4±0.2 26 26.7
2 1.0 32/0.2 0.6 6.7±0.2 19.5 20.0
2 1.5 30/0.25 0.7 7.7±0.2 13.3 13.7
2 2.5 49/0.25 0.8 9.4±0.2 7.98 8.21
3 0.75 24/0.2 0.6 6.8±0.2 26 26.7
3 1.0 32/0.2 0.6 7.2±0.2 19.5 20.0
3 1.5 30/0.25 0.7 8.5±0.2 13.3 13.7
3 2.5 49/0.25 0.8 10.2±0.2 7.98 8.21
4 0.75 24/0.2 0.6 7.4±0.2 26 26.7
1.0 32/0.2 0.6 8.0±0.2 19.5 20.0
1.5 30/0.25 0.7 9.4±0.2 13.3 13.7
2.5 49/0.25 0.8 11.0±0.3 7.98 8.21
5 0.75 24/0.2 0.6 8.4±0.2 26 26.7
1.0 32/0.2 0.6 8.8±0.2 19.5 20.0
1.5 30/0.25 0.7 10.6±0.3 13.3 13.7
2.5 49/0.25 0.8 12.4±0.3 7.98 8.21
RVB
Copper conductor PVC insulated flat flexible connector cable (electrical wire)
Duplex electric cable
1.Conductor: Multi-Unit bare copper wire strands
2.Insulation: polyvinyl chloride (PVC)
3.Rated Voltage: UO / U for 300/300 V
4.Temperature Rating: long-term temperature should be no more than 70 degree C
……………………ETC.
Certificate
- 3C CE
Main Products
wire, cable,
