Nominal Cross Section | Conductor | Conductor | Conductor | Conductor | Insulation | Overall Diameter | Overall Diameter |
---|---|---|---|---|---|---|---|
- | No. of Strands | Diameter of Strand | Outer Diameter | Electric Resistance at 20°C | Standard Thickness | Standard | Maximum |
mm² | - | mm | mm | mΩ/m | mm | mm | mm |
0.5 | 7 | 0.32 | 1.0 | 32.7 | 0.60 | 2.2 | 2.4 |
0.85 | 16 | 0.26 | 1.2 | 22 | 0.60 | 2.4 | 2.6 |
1.25 | 16 | 0.32 | 1.5 | 14.3 | 0.60 | 2.7 | 2.9 |
2 | 26 | 0.32 | 1.9 | 8.81 | 0.60 | 3.1 | 3.4 |
3 | 41 | 0.32 | 2.4 | 5.59 | 0.70 | 3.8 | 4.1 |
5 | 65 | 0.32 | 3.0 | 3.52 | 0.80 | 4.6 | 4.9 |
8 | 50 | 0.45 | 3.7 | 2.32 | 0.90 | 5.5 | 5.8 |
15 | 84 | 0.45 | 4.8 | 1.38 | 1.10 | 7.0 | 7.4 |
20 | 41 | 0.80 | 6.0 | 0.887 | 1.10 | 8.2 | 8.8 |
30 | 70 | 0.80 | 8.0 | 0.520 | 1.40 | 10.8 | 11.5 |
0.5f | 20 | 0.18 | 1.0 | 36.7 | 0.60 | 2.2 | 2.4 |
0.75f | 30 | 0.18 | 1.2 | 24.4 | 0.60 | 2.4 | 2.6 |
1.25f | 50 | 0.18 | 1.5 | 14.7 | 0.60 | 2.7 | 2.9 |
Features
- Application :
- Insulated low-tension wires for automobiles, motorcycles and other motor vehicles. JIS C 3406 compliant.
- Materials/Standard :
- Conductor : Soft-annealed copper wires in compliance with JIS C 3102.
- Insulation : Vinyl (PVC) insulated. In compliance with JIS C 3406 and RoHS Directive.
- Temperature rate :
- 80°C