Nominal Cross Section | Conductor | Conductor | Conductor | Conductor | Insulation | Overall Diameter | Overall Diameter |
---|---|---|---|---|---|---|---|
- | No. of Strands | Diameter of Strand | Outer Diameter | Electric Resistance at 20°C | Standard Thickness | Standard | Maximum |
mm² | - | mm | mm | mΩ/m | mm | mm | mm |
0.5 | 7 | 0.32 | 1.0 | 32.7 | 0.50 | 2.0 | 2.2 |
0.85 | 16 | 0.26 | 1.2 | 20.8 | 0.50 | 2.2 | 2.4 |
1.25 | 16 | 0.32 | 1.5 | 14.3 | 0.60 | 2.7 | 2.9 |
2 | 26 | 0.32 | 1.9 | 8.81 | 0.60 | 3.1 | 3.4 |
3 | 41 | 0.32 | 2.4 | 5.59 | 0.70 | 3.8 | 4.1 |
5 | 65 | 0.32 | 3.0 | 3.52 | 0.80 | 4.6 | 4.9 |
8 | 50 | 0.45 | 3.7 | 2.32 | 0.80 | 5.3 | 5.6 |
0.5f | 20 | 0.18 | 1.0 | 36.7 | 0.50 | 2.0 | 2.2 |
0.75f | 30 | 0.18 | 1.1 | 24.4 | 0.50 | 2.2 | 2.4 |
1.25f | 50 | 0.18 | 1.5 | 14.7 | 0.60 | 2.7 | 2.9 |
Features
- Application :
- Crosslinked PE insulated and higher heat-resistant low-tension wires for automobiles, motorcycles and other motor vehicles.
- JASO D 608-92 compliant.
- Materials/Standard :
- Conductor : Soft-annealed copper wires in compliance with JIS C 3102.
- Insulation : Crosslinked PE insulated. In compliance with JASO D 608-92 and RoHS Directive.
- Temperature rate :
- 40°C ~ 125°C
Main Products
Halogen Free Thin-Wall Cable, Halogen Free Ultra Thin-Wall Cable, Thin-wall cable, Cable, Wire
Related Products
Contact Detail
-
Sales ContactMs. Ching Tsai
-
AddressNo. 14-3, Wu Lin St., Shulin Dist., New Taipei City 238, Taiwan.
-
Tel886-2-26835095
-
Fax886-2-26836179
-
E-mail
-
URL